Can a vortex flowmeter output both HART and RS485 signals?
Whether a vortex flowmeter can output both HART and RS485 signals depends on the specific flowmeter model and manufacturer’s design. The following is a detailed analysis of this issue:
Features of HART and RS485 protocols
HART Protocol:
- 1. It is a mixed analogue and digital communication protocol that can superimpose digital signals on 4-20أماه analogue signals.
- 2. It supports bi-directional communication and is capable of transmitting equipment status, diagnostic information, and so on.
- 3. It is suitable for applications requiring remote monitoring and diagnosis.
RS485 protocol:
- 1. It is a digital communication protocol that supports multi-point communication and long distance transmission (up to 1200 metres).
- 2. With high transmission rate and strong anti-interference ability, it is usually used for industrial communication protocols such as Modbus RTU or Profibus.
- 3. It is suitable for occasions requiring high-speed data transmission and multi-device networking.

Feasibility of simultaneous output of HART and RS485 signals
Technology realisation:
- 1. Technically, vortex flowmeters can support both HART and RS485 signal outputs, but this requires the flowmeter to have an independent communication module and processing circuitry inside.
- 2. Some high-end vortex flowmeters may support multi-protocol output, but the specific implementation should refer to the manufacturer’s technical specifications.
Practical applications:
Most vortex flowmeters typically support only one communication protocol (e.g., HART or RS485) because supporting both protocols increases hardware complexity and cost.
If you need to use HART and RS485 at the same time, you can consider the following options:
- 1. Choose a flowmeter that supports multiple protocols: Some high-end models may support HART and RS485 outputs at the same time.
- 2. Use a signal converter: Convert the HART signal to RS485 or vice versa with an external signal converter.
- 3. Time-sharing multiplexing: If the flowmeter supports protocol switching, it is possible to use different protocols at different times.
Suggestions for selection
- 1. Confirmation of requirements: Clarify whether it is necessary to use HART and RS485 signals at the same time, or whether it is possible to use them at separate times.
- 2. Check the technical specifications: When choosing vortex flowmeter, carefully check the technical specifications provided by the manufacturer to confirm whether multi-protocol output is supported.
- 3. Consult the manufacturer: If the technical specifications are not clear, you can directly consult the manufacturer or supplier for detailed technical support.
Whether a vortex flowmeter can output both HART and RS485 signals depends on the specific model and manufacturer’s design. In most cases, vortex flowmeters support only one communication protocol, but some high-end models may support multi-protocol output. If both HART and RS485 signals are required, consider selecting a flowmeter that supports multiple protocols, or use an external signal converter to achieve protocol conversion. When selecting a model, it is recommended to carefully review the technical specifications or consult the manufacturer to ensure that the actual needs are met.