Introduction to vortex flowmeters for high temperature steam

Vortex flowmeter can measure liquid, gas and steam media. And vortex flowmeter has a small pressure loss, ከፍተኛ ትክክለኛነት, large range, in the measurement of volume flow by the fluid density, temperature, ግፊት, viscosity and other parameters of the influence is very small and so on. Currently has been widely used in petroleum, ኬሚካል, ፋርማሲዩቲካል, food, electric power and other industries. Vortex flowmeter can also measure high temperature media, to ensure accurate measurement in high temperature and pressure environment.

High temperature steam vortex flowmeter parameters

Product ለከፍተኛ ሙቀት እንፋሎት የቮርቴክስ ፍሰት መለኪያ
Measuring medium Liquids, ጋዞች, እንፋሎት
የስም ግፊት 2.5MPa, 4.0MPa
መካከለኛ ሙቀት -20℃~+350℃
Accuracy 1.0% 1.5%
የውጤት ምልክት Pulse signal, 4-20mA current signal
Installation Wafer connection: DN15-DN300(priority PN2.5MPa); Flange connection: DN15-ዲኤን50(priority PN2.5MPa);DN65-DN200(priority PN1.6MPa);DN250-DN300(priority PN1.0MPa)
Power supply DC24V, DC12V, DC3.6V Lithium battery
Ingress protection IP65
Frequency RS485 communication (Modbus RTU)
Range Ratio Gas density:1.2kg/m3, Range ratio: 8:1

How to select vortex flowmeter for high temperature steam?

The so-called high-temperature steam vortex flowmeter as the name suggests is able to measure the temperature of the gas or liquid, Meacon high-temperature steam vortex flowmeter can measure the high temperature upper limit temperature of 350 ℃ liquid or gas media, for the site of high temperature media such as thermal oil, high-temperature steam and other media. Measurement of high-temperature site should be selected with temperature and pressure compensation vortex flowmeter, because the medium temperature is too high, there will be a temperature difference will cause the vortex flowmeter error caused by the inaccurate readings. So the vortex flowmeter for high temperature steam should be selected with temperature and pressure compensation.

High-temperature steam vortex flowmeter during the selection period also needs to be based on the measurement medium, temperature, flow range, calibre, working pressure and other parameters to be selected to better meet the site use. In addition, high-temperature steam vortex flow meter on the installation point of the upstream and downstream straight section has certain requirements, otherwise it will affect the media flow field in the pipeline, affecting the measurement accuracy of the instrument.

Determine the necessary selection parameters:

Wiring design of vortex flowmeters for high temperature steam

Three-wire vortex flowmeter wiring design for output frequency signals

Output frequency signal of the three-wire flow sensor using DC24V or DC12V power supply, generally through the three-core shielded cable line (RWP3 × 0.5mm) and display instrumentation or computer connected to the shielding should be reliably connected to the amplifier shell grounding screws. Shielded cable line selection should be suitable for the site environmental requirements, in addition to shielded cable line to be separated from other strong power power lines, not parallel to the line.

Two-wire vortex flowmeter wiring design with standard 4~20mA current signal output:

Output standard 4 ~ 20mA current signal two-wire transmitter with DC24V power supply, generally through the two-core shielded cable line (RWP3 × 0.5mm) and display instrumentation or computer connected to the shielding should be reliably connected to the amplifier shell grounding screws. Shielded cable line selection should be suitable for the site environmental requirements, in addition to shielding the cable line to be separated from other strong power power lines, not parallel to the line.

Vortex flowmeter wiring design with RS-485 communication interface function:

The vortex flowmeter for high temperature steam with RS-485 communication adopts DC24V power supply and four-wire transmission with other devices.

How to install vortex flowmeter for high temperature steam?

Cveat:

Minimise the impact of steam hammer on the vortex generator in the pipeline. Vortex flow meters should not be used when vibration is high and cannot be eliminated.

Commissioning instructions: