The Meacon vortex flowmeter for high temperature steam is a steam flowmeter designed to measure saturated steam with automatic density compensation for saturated steam. Flow and temperature compensated sensors in one unit.
Vortex flowmeter can measure liquid, gas and steam media. And vortex flowmeter has a small pressure loss, saktësi të lartë, large range, in the measurement of volume flow by the fluid density, temperature, presioni, viscosity and other parameters of the influence is very small and so on. Currently has been widely used in petroleum, kimike, farmaceutike, food, electric power and other industries. Vortex flowmeter can also measure high temperature media, to ensure accurate measurement in high temperature and pressure environment.
Product | Matës i rrjedhës Vortex për avull me temperaturë të lartë |
Measuring medium | Liquids, gazet, avulli |
Presioni nominal | 2.5MPa, 4.0MPa |
Temperatura mesatare | -20℃~+350℃ |
Accuracy | 1.0% 1.5% |
Sinjali i daljes | Pulse signal, 4-20mA current signal |
Installation | Wafer connection: DN15-DN300(priority PN2.5MPa); Flange connection: DN15-DN50(priority PN2.5MPa);DN65-DN200(priority PN1.6MPa);DN250-DN300(priority PN1.0MPa) |
Power supply | DC24V, DC12V, DC3.6V Lithium battery |
Ingress protection | IP65 |
Frequency | RS485 communication (Modbus RTU) |
Range Ratio | Gas density:1.2kg/m3, Range ratio: 8:1 |
The so-called high-temperature steam vortex flowmeter as the name suggests is able to measure the temperature of the gas or liquid, Meacon high-temperature steam vortex flowmeter can measure the high temperature upper limit temperature of 350 ℃ liquid or gas media, for the site of high temperature media such as thermal oil, high-temperature steam and other media. Measurement of high-temperature site should be selected with temperature and pressure compensation vortex flowmeter, because the medium temperature is too high, there will be a temperature difference will cause the vortex flowmeter error caused by the inaccurate readings. So the vortex flowmeter for high temperature steam should be selected with temperature and pressure compensation.
High-temperature steam vortex flowmeter during the selection period also needs to be based on the measurement medium, temperature, flow range, calibre, working pressure and other parameters to be selected to better meet the site use. In addition, high-temperature steam vortex flow meter on the installation point of the upstream and downstream straight section has certain requirements, otherwise it will affect the media flow field in the pipeline, affecting the measurement accuracy of the instrument.
Determine the necessary selection parameters:
Three-wire vortex flowmeter wiring design for output frequency signals:
Output frequency signal of the three-wire flow sensor using DC24V or DC12V power supply, generally through the three-core shielded cable line (RWP3 × 0.5mm) and display instrumentation or computer connected to the shielding should be reliably connected to the amplifier shell grounding screws. Shielded cable line selection should be suitable for the site environmental requirements, in addition to shielded cable line to be separated from other strong power power lines, not parallel to the line.
Two-wire vortex flowmeter wiring design with standard 4~20mA current signal output:
Output standard 4 ~ 20mA current signal two-wire transmitter with DC24V power supply, generally through the two-core shielded cable line (RWP3 × 0.5mm) and display instrumentation or computer connected to the shielding should be reliably connected to the amplifier shell grounding screws. Shielded cable line selection should be suitable for the site environmental requirements, in addition to shielding the cable line to be separated from other strong power power lines, not parallel to the line.
Vortex flowmeter wiring design with RS-485 communication interface function:
The vortex flowmeter for high temperature steam with RS-485 communication adopts DC24V power supply and four-wire transmission with other devices.
Cveat:
Minimise the impact of steam hammer on the vortex generator in the pipeline. Vortex flow meters should not be used when vibration is high and cannot be eliminated.
Commissioning instructions:
Ne i vlerësojmë reagimet tuaja! Ju lutemi plotësoni formularin më poshtë, në mënyrë që të mund t'i përshtatni shërbimet tona për nevojat tuaja specifike.
Klikoni butonin për të marrë informacione për produktin dhe kuotat në WhatsApp.
MERR CITA
Hetim